29
RT-5SW LED display
(visible when RC-300W is removed)
When the RC-300W is detached from the unit, a LED is visible. It provides a quick status check
on the RT-5SW as follows:
Yellow flashing:
Auto-leveling or grade setting is in process.
The rotary head is not rotating.
Yellow ON solid:
Auto-leveling grade setting is complete.
The rotary head is active and emits the laser beam.
Red quick flashing:
1) The instrument is positioned beyond auto-leveling range (±5°).
Reposition the instrument into range and LED should begin normal flashing.
2) Error has occurred. If Height Alert function is active, unit may have been
disturbed (see previous section). RC-300W will also indicate error code.
See “Error Display” section.
Red flashing:
Indicates the current channel on the remote control for the instrument. The
channel on the instrument can be identified from the number of blinking times
after long illumination.
You can stop the auto-levelling function. Refer to “Function Mode” on page 33 to stop
the function.