Error Display
Error code Description Countermeasure
RT BATT
LOW
The battery of the RT-5SW is dead.
Replace or recharge the batteries.
If replaced, return the RC-300W to the RT-5SW
after new batteries are installed.
HI ALERT
The height alert function is working.
Turn the power key OFF and ON again, the auto-
leveling function will start again.
LEVELING
RANGE
LIMIT
The instrument is inclined more than the
auto-leveling range.
Set up the instrument within the ± 5 degree auto-
leveling range.
CAL LIMIT
In the checking and adjusting mode, the
correction value is out of range.
Turn the power key OFF and ON again, repeat from
the beginning.
E-05
The rotary head can not rotate for some
reason.
Turn the power key OFF and ON again.
RETRY
The instrument can not find the target in the
Automatic alignment/Automatic grade
setting mode.
Confirm the target or setting direction of the
instrument, repeat from the beginning.
RETRY
RANGE
LIMIT
The location where the target is placed
exceeds the measuring range during
Automatic alignment and Automatic grade
setting.
Confirm the target or setting direction of the
instrument, repeat from the beginning.
E-40’s
E-90’s
Abnormality in internal memory of the
instrument.
Turn the power key OFF and ON again.