33
Function Mode
The RT-5SW has seven function modes the user can set.
1) Laser Output Power (POWER)
Two levels of laser output are possible:
HIGH (4.5mW) LO (2.5mW)
The high power mode should be used when necessary due to long range requirement,
otherwise the low power mode will provide longer battery life.
2) Sensitivity Level (LEVEL)
The sensitivity mode allows the user to select the vibration level that is necessary
to cause the unit to re-activate auto-leveling. This function is valuable when the RT-
5SW in windy or other conditions that cause unnecessary auto-leveling activity.
Two sensitivity levels can be set, plus manual operation.
Level One [1]: Least sensitive. Auto-leveling will not activate with moderate vibration.
Level Two [2]: Most sensitive. Smallest vibration will cause auto-leveling activity.
M(Manual): Auto-leveling function, Auto-alignment and Setting grade are turned off.
1) Laser Output Power (POWER) 2) Sensitivity Level (LEVEL) 3) Height Alert (ALERT)
4) Alarm Signal (COM) 5) Changing Masking Mode 6) Setting the target
7) Channel Setting
Do not use manual level [M] except for special circumstances. If manual [M] is
selected, the Automatic alignment, Automatic grade setting and X,Y-grade setting
function will not operate and leveling and grade setting precision cannot be
assured.