26
Single axis
1 Press the Auto-alignment key on the RC-300W, select [GRADE SET 1] and press the [ENT]
key to finish input.
2 Using the arrow keys, select the grade axis that is roughly aligned to the alignment target (Y+,
X-, Y-, X+). Press the [ENT] key to finish input.
3 During the grade setting, [PROCESSING ...] is displayed. After the grade setting is finished,
the one-axis setting will be displayed (normal display).
Dual axes
1 Press the Auto-alignment key on the RC-300W, select [GRADE SET 2] and press the [ENT]
key to finish input.
2 Using the arrow keys, select the 1st axis that is roughly aligned to the alignment target (Y+, X-
, Y-, X+). Press the [ENT] key to finish input. During the grade setting for the 1st axis, [1st
PROCESSING ...] is displayed.
3 When the setting for the 1st axis is finished, the 2nd axis setup screen will appear. Use the
arrow key (Y+, X-, Y-, X+) to select the direction of the 2nd axis and then press the [ENT] key
to establish that direction.
During the grade setting for the 2nd axis, [2nd PROCESSING ...] is displayed. After the grade
setting is finished, Dual axes grade display will appear (normal display).