42
1) The Ni-MH BT-63Q rechargeable battery can be charged while using the laser.
2) The Ni-MH BT-63Q rechargeable battery can be charged when the battery holder is
removed from the instrument. This allows the option of alternately using two battery
packs to always maintain a fully charged pack.
3) The Ni-MH BT-63Q rechargeable battery can be removed from the DB-64C battery
holder and four “D” cell alkaline batteries can be installed.
4)The DB-64 dry cell battery holder cannot be used to charge the BT-63Q Ni-MH battery
pack. Use the DB-64C charging battery holder instead.
1) Recharging should take place in a room with an ambient temperature range of 10°C
to 40°C (50°F to 104°F).
2) The battery source will discharge when stored and should be checked before using
with instrument.
3) Be sure to charge stored battery source every 3 or 6 months and store in a place at
30°C or below.
If you allow the battery to become completely discharged, it will have an effect on
future charging.
BT-63Q