EasyManua.ls Logo

Topcon RT-5SW - Detective Range and Precision; Replacing Battery (LS-70 A;70 B)

Topcon RT-5SW
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
Detective
range
(LS-70A/70B)
Mode
Display
HIGH NORMAL
Replacing Battery (LS-70A/70B)
1 Press the lid in the
direction of the arrow to
lift.
2 Remove the battery and
replace with a new 9v
alkaline battery.
3 Press the lid down and
click to close.
Remote display with coil cord (LS-70A
only)
Optional remote display connects to the back of
the LS-70A. The remote LCD display can be
positioned up to 5m (16 ft) from the laser sensor.
LS-70A
±1mm/±.0032 ft
(2mm/.0064 ft width)
±2mm/±.0064 ft
(4mm/.013 ft
width)
LS-70B
±1mm/±.0032 ft
(2mm/.0064 ft width)
±5mm/±.016 ft
(10mm/.032 ft width)
±10mm/±.033 ft
(20mm/.066 ft width)
±15mm/±.005 ft
(30mm/.010 ft width)
More than ±15mm/.05 ft
Laser sensor has been moved above or
below the laser beam.
Move sensor in direction of arrow to
receive laser.
Connector
Coil cord
Remote display
LS-70A