EasyManua.ls Logo

Toro 07367 - Changing the High Flow Hydraulic Oil and Filter (TC Models Only); Raising the Box in an Emergency

Toro 07367
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure79
1.Hydrauliclter2.Highowhydraulicslter
3.Lubricatethegasketonthenewlter.
4.Ensurethattheltermountingareaisclean.Screw
thelteronuntilthegasketcontactsthemounting
plate.Thentightenthelterone-halfturn.
5.Starttheengineandletitrunforabouttwominutes
topurgeairfromthesystem.Stoptheengineand
checkthehydraulicoillevelandforleaks.
ChangingtheHighFlow
HydraulicOilandFilter(TC
Modelsonly)
ServiceInterval:Aftertherst10hours—Change
thehighowhydraulicoillter(TC
Modelsonly).
Every800hours—Changethehigh
owhydraulicoilandlter(TC
Modelsonly).
Thereservoirislledwithapproximately4USgallons
(15l)ofhighqualityhydraulicuid.Appropriate
hydraulicoilsarelistedbelow .
ToroPremiumAllSeasonHydraulicFluid(Available
in5gallonpailsor55gallondrums.Seepartscatalogor
Torodistributorforpartnumbers.)
Alternateuids:IftheTorouidisnotavailable,
anotherconventionalpetroleum–baseduidmaybe
usedprovideditmeetsthefollowingmaterialproperties
andindustryspecications.Consultwithyourlubricant
distributortoidentifyasatisfactoryproduct.Note:
Torowillnotassumeresponsibilityfordamagecaused
byimpropersubstitutions,souseonlyproductsfrom
reputablemanufacturerswhowillstandbehindtheir
recommendation.
HighViscosityIndex/LowPourPointAntiwear
HydraulicFluid,ISOVG46
MaterialProperties:
Viscosity—ASTMD445cSt@40ºC:44to48/cSt
@100ºC:7.9to8.5
ViscosityIndex,ASTMD2270—140to152
PourPoint,ASTMD97—-35ºFto-46ºF
FZG,Failstage—11orbetter
Watercontent(newuid)—500ppm(maximum)
IndustrySpecications:
VickersI-286-S,VickersM-2950-S,DenisonHF-0,
Vickers35VQ25(EatonATS373-C)
Note:Manyhydraulicuidsarealmostcolorless,
makingitdifculttospotleaks.Areddyeadditivefor
thehydraulicsystemoilisavailablein2/3oz.(20ml)
bottles.Onebottleissufcientfor4–6gal(15–221)
ofhydraulicoil.Orderpartno.44-2500fromyour
authorizedTorodistributor.
Note:Iftheoilbecomescontaminated,contactyour
localTorodistributorbecausethesystemmustbe
ushed.Contaminatedoilmaylookmilkyorblackwhen
comparedtocleanoil.Theserviceintervalmayneed
tobeincreasedifusingmultipleattachmentsastheoil
maybecomecontaminatedquickerwiththemixingof
differenthydraulicoils.
1.Cleantheareaaroundthehighowltermounting
area(
Figure79).Placeadrainpanunderthelter
andremovethelter.
Note:Iftheoilisnotgoingtobedrained,
disconnectandplugthehydrauliclinegoingtothe
lter.
2.Lubricatethenewltersealinggasketandhandturn
thelterontothelterheaduntilthegasketcontacts
thelterhead.Thentightenit3/4turnfurther.The
ltershouldnowbesealed.
3.Fillthehydraulicreservoirwithapproximately4US
gallons(15l)ofhydraulicoil.
4.Startthemachineandrunitatidleforabouttwo
minutestocirculatetheuidandremoveanyair
trappedinthesystem.Stopthemachineandrecheck
theuidlevel.
5.Verifytheoillevel.
6.Disposeoftheoilproperly.
RaisingtheBoxinan
Emergency
Theboxcanberaisedinanemergencywithoutstarting
theenginebycrankingstarterorbyjumpinghydraulic
system.
56