Figure6
1.Cover4.Geartoothsensor
2.Screw(M6x1.00x12)5.Seal
3.Springwasher(M6)6.Forwardface
5.Installthegeartoothsensorusingthescrew(M6x1.00
x12)andspringwasher(M6)asshowninFigure6.
6.Installthemuferbracketoverthenewcoverassembly.
4
InstallingthePower
Take-Off(PTO)Kit
(forWorkman
®
3000,4000
seriesonly)
NoPartsRequired
Procedure
SuspendthesetupoftheWorkman200SpraySystemat
thistimetoinstallthePTOkit.Refertotheaccompanying
InstallationInstructionsformoreinformation.
Continuetothenextsteponcecompleted.
5
InstallingtheElectrical
Harness
Partsneededforthisprocedure:
1Fuseblock
1
Fuse(10amp)
2
Thermalbreaker(30amp)
1
Hexscrew(#10-24x3/4inch)
1
Phillipsscrew(#10-24x3/4inch)
2
Locknut(#10-24)
1Wireharness
1
Jumperharness(HDseriesonly)
1
Starwasher
8Wiretires
1Fusedecal
forWorkman
®
3000,4000series
1.Removethescrewsholdingthefronthoodtothe
frame.Disconnectthewiringharnessattachedtothe
headlights.Removethehoodtoaccesstheelectrical
wiring.
2.Locatetheelectricalwireharnessandfuseblockin
looseparts.
3.Removethetwoscrewsfromtheexistingfuseblock
andslidethenewfuseblockintothegroovesofthe
existingblock.
4.Wiretheelectricalharnesstothefuseblockbyjoining
thewiresintheharnesstothecorrespondingwire
connectorsinthebackofthefuseblock(Figure7).