Lubrication
GreasingtheSprayerSystem
ServiceInterval:Every50hours
Every100hours
Lubricateallbearingsandbushingsafterevery100hoursor
onceayear,whicheveroccursrst.
GreaseType:No.2GeneralPurposeLithiumBaseGrease
1.Wipethegreasettingcleansothatforeignmatter
cannotbeforcedintothebearingorbushing.
2.Pumpgreaseintothebearingorbushing.
3.Wipeoffexcessgrease.
Figure48
Pump(Donotovergrease,greasewillnotpurge)
1.Greasepoint
GreasingtheBoomHinges
ServiceInterval:Every100hours
Important:Iftheboomhingeiswashedwithwater,
allwateranddebrismustbeclearedfromthehinge
assemblyandfreshgreasemustbeapplied.
GreaseType:No.2general-purposelithiumbasegrease.
1.Wipethegreasettingscleansothatforeignmatter
cannotbeforcedintothebearingorbushing.
2.Pumpgreaseintothebearingorbushingateachtting
Figure49.
Figure49
Rightboom
1.Greasetting
3.Wipeoffexcessgrease.
4.Repeattheprocedureforeachboompivot.
GreasingtheActuatorRod
Bearings
ServiceInterval:Every400hours/Yearly(whichevercomes
rst)
GreaseType:No.2general-purposelithiumbasegrease.
1.Extendtheboomstothesprayposition.
2.Removethecottezrpinfromthepivotpin(Figure50).
40