CalibratingtheSprayPro
Monitor
Figure42
1.LCDscreen
6.Applicationrate11.Reset,calibrationbutton
16.Selectunits
2.Selectiondial7.SubArea12.Calibrate,calibrationbutton
17.Width
3.Totalarea8.Distance13.Decrease,calibration
button
18.Speedcalibration
4.Speed9.Subvolume
14.Increase,calibrationbutton19.Flowmetercalibration
5.Unitsofmeasure
10.Totalvolume15.Boomselection20.LED
TheSprayPromonitorhasacalibrationmodethatallows
youtochangevarioussettingstocustomizethedisplayand
calibratethemonitortoyourneeds.Youcancalibrateor
changethefollowingsettings:
BoomWidth
UnitsofMeasure
Speed
Flowmeter
SettingtheBoomWidth
Thedefaultsettingsfortheboomwidthsare80inches
(2.03m)fortherightandleftboomsand60(1.524m)forthe
centerboom.Thisisbasedon4nozzlesontherightand
leftboomsand3onthecenterboomallspaced20inches
(50.8cm)apart.Ifyouchangethespacingofthenozzles,
youshouldchangetheboomwidthtoreectyourchanges
asfollows:
1.Stopthesprayerandsettheparkingbrake.
2.SetthemasterboomswitchtotheOffposition.The
monitordisplays“HOLD”.
3.PressandholdtheCalibratebuttonuntilthemonitor
displays“CALHOLD”andtheredlightonthe
monitorilluminates.
4.TurntheselectiondialtotheBoomSelect(orTotal
Area)position.
5.UsetheIncreaseorDecreasecalibrationbuttonsto
selecttheboomforwhichyouwishtochangethe
width,where1istheleftboom,2isthecenterboom,
and3istherightboom.
6.TurntheselectiondialtotheWidth(orSubArea)
position.
7.UsetheIncreaseorDecreasecalibrationbuttonsto
changetheboomwidthasneeded.
8.Repeatsteps4through7fortheotherboomsas
needed.
9.PresstheCalibratebuttonuntiltheredlightturnsoff.
Youcanalsoexitthecalibrationmodebydrivingthe
sprayer.
SettingtheUnitsofMeasure
ThedefaultsettingfortheunitsofmeasureisUS.Youcan
alsochangetheunitstoSI(metric)orTURF.