ElectricalSystem
Maintenance
Fuses
Thereisafuseblockaddedtotheelectricalsystem.Itis
locatedbeneathdashboardwiththeexistingfuseblock.
Thetwothermalbreakersaccommodatetheleftandright
actuatorsindependently.Theyareusedtodisruptpower
totheactuatorswhenoverheatedtoavoiddamagingthe
internalmotoroftheactuators.Therearealsobreakersinthe
actuator'sthemselvesthatcanbetripped.
Note:Oncethethermalbreakerhasbeentrippedthesystem
mustbeallowedtocooldownbeforeoperationtoresume.
SpraySystem
Maintenance
WARNING
Chemical substances used in the spray system may
be hazardous and to xic to y ou, bystander s, animals,
plants, soils or other pr oper ty .
Carefullyreadandfollowthechemical
warninglabelsandMaterialSafetyData
Sheets(MSDS)forallchemicalsusedand
protectyourselfaccordingtothechemical
manufacturer'srecommendations.Forexample,
useappropriatePersonalProtectiveEquipment
(PPE)includingfaceandeyeprotection,gloves,
orotherequipmenttoguardagainstpersonal
contactwiththechemical.
Keepinmindthattheremaybemorethanone
chemicalusedandinformationoneachshould
beassessed.
R efuse to operate or w or k on the spray er if this
inf or mation is not a v aila ble!
Beforeworkingonaspraysystemmakesurethe
systemhasbeentriplerinsedandneutralized
accordingtotherecommendationsofthe
chemicalmanufacturer(s)andallofthevalves
havebeencycledthreetimes.
Verifythereisanadequatesupplyofcleanwater
andsoapnearby,andimmediatelywashoffany
chemicalsthatcontactyou.
InspectingtheHoses
ServiceInterval:Every200hours
Every400hours/Yearly(whichever
comesrst)
Examineeachhoseinthespraysystemforcracks,leaksor
otherdamage.Atthesametime,inspecttheconnectionsand
ttingsforsimilardamage.Replaceanyhosesandttingsif
damaged.
PumpMaintenance
InspectingthePump
ServiceInterval:Every400hours/Yearly(whichevercomes
rst)—Inspectthepumpdiaphragmand
replaceifnecessary.(seeanAuthorized
ToroServiceDistributor)
Every400hours/Yearly(whichever
comesrst)—Inspectthepressure
dampenerbladderandreplaceif
42