Problem
PossibleCauseCorrectiveAction
1.Thesprayerwidthisnotcorrectly
entered.
1.CheckandsettheappropriateWidthin
thecalibrationmode.
2.Thespeedsensorisnotcalibrated
correctly.
2.Calibratethespeedsensor.
TheAreaisinaccurate.
3.Thespeedsensorisdamaged.
3.ContactyourAuthorizedService
Dealer.
1.Thespeedsensorisnotcalibrated
correctly.
1.Calibratethespeedsensor.
TheDistanceisinaccurate.
2.Thespeedsensorisdamaged.
2.ContactyourAuthorizedService
Dealer.
1.Themonitorcableisloose.
1.Connectthemonitorcable.
2.Theowmeterisdirtyorclogged.2.Cleantheowmeter.
3.Theowmeterisnotcalibrated
correctly.
3.Calibratetheowmeter.
ThemonitordoesnotdisplayApplication
RateorTotalVolume.
4.Theowmeterisdamaged.4.ContactyourAuthorizedService
Dealer.
1.Theowmeterisdirtyorclogged.1.Cleantheowmeter.
2.Theowmeterisnotcalibrated
correctly.
2.Calibratetheowmeter.
TheTotalVolumeisinaccurate.
3.Theowmeterisdamaged.3.ContactyourAuthorizedService
Dealer.
Themonitordisplays6553.5wheninthe
ApplicationRatesetting.
1.Themonitorisnotreceivingdatafrom
thespeedsensor.
1.ContactyourAuthorizedService
Dealer.
Themonitoriserraticinoperation.1.Atwo-wayradioistooclosetothe
monitororitscables.
1.Keeptwo-wayradiosawayfromthe
monitoranditscables.
Thedisplayedmeasurementsdonotmake
sense.
1.TheUnitsofMeasurementissettoa
systemotherthanwhatyouexpect.
1.ChecktheUnitsofMeasurementto
ensurethatitissetcorrectly.
Themonitorreads“OFL.”
1.Thedatahasexceededthemaximum
allowed.
1.Pressandholdthe[Reset]buttonto
clearthemonitor.