ChangingtheHydraulicFilter
ServiceInterval:Every1,000hours—Ifyou
areusingtherecommended
hydraulicuid,replacethe
hydrauliclter(sooneriftheservice
intervalindicatorisintheredzone).
Every800hours—Ifyouarenotusingthe
recommendedhydraulicuidorhaveever
lledthereservoirwithanalternativeuid,
replacethehydrauliclter(sooneriftheservice
intervalindicatorisintheredzone).
UseagenuineTororeplacementlter(PartNo.
86-3010).
Important:Usinganyotherltermayvoidthe
warrantyonsomecomponents.
1.Performthepre-maintenanceprocedure;refer
toPreparingtheMachineforMaintenance(page
37).
2.Pinchoffthehosetothelter-mountingplate.
3.Cleanaroundthelter-mountingarea,placea
drainpanunderthelter,andremovethelter
(Figure66).
g195308
Figure66
1.Hydrauliclter
4.Lubricatethenewltergasketandllthelter
withhydraulicuid.
5.Ensurethattheltermountingareaiscleanand
screwthelteronuntilthegasketcontactsthe
mountingplate;thentightenthelter1/2turn.
6.Releasethehosetothelter-mountingplate.
7.Starttheengineandletitrunforapproximately
2minutestopurgeairfromthesystem.
8.Shutofftheengineandcheckforleaks.
CheckingtheHydraulicLinesand
Hoses
ServiceInterval:Beforeeachuseordaily
Every2years—Replacemovinghoses.
Checkthehydrauliclinesandhosesforleaks,kinked
lines,loosemountingsupports,wear,loosettings,
weatherdeterioration,andchemicaldeterioration.
Makeallnecessaryrepairsbeforeoperatingthe
machine.
53