Micro-Master Touch User Guide
109
© 2014 Toro Australia Pty Ltd Ver 1.2, June 2014
Analogue 4mA Calibration
Shows the 4mA calibration measurement for the flow meter. This value is the reading that will be
displayed by the controller when the 4-20mA sensor is measuring 4mA current. Selecting the 4mA
calibration button and clicking Edit will display the Number Edit screen.
Analogue 20mA Calibration
Shows the 20mA calibration, or full scale measurement for the flow meter. This value is the reading
that will be displayed by the controller when the 4-20mA sensor is measuring 20mA current.
Selecting the 20mA calibration button and clicking Edit will display the Number Edit screen.
Analogue Current Value
This item shows the current measured value for the sensor. The value shown is in the units specified
in the Analogue Unit item.
Analogue Current total
This item shows the totalised value for the sensor. The value shown is in the unit/hours specified in
the Analogue Unit item.
Analogue Trigger
This item sets the level at which the analogue sensor becomes triggered. Selecting the Trigger item
and clicking Edit will display the Number Edit screen.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toro Micro-Master Series and is the answer not in the manual?

Toro Micro-Master Series Specifications

General IconGeneral
BrandToro
ModelMicro-Master Series
CategoryController
LanguageEnglish

Related product manuals