14.8.4 Analogue Status and Totals
The Status and Totals screen is the only page of Advanced Analogue Sensor Parameters and is
displayed by pressing the icon on the Analogue Sensor Edit screen.
Figure 80 - Analogue Sensor Status and Totals
Analogue Sensor Status
This section shows the current status of the analogue sensor.
Analogue Sensor Totals
This section shows the current totals for the analogue sensor. Clicking the clear button will clear the
totals.
14.9
Switch Sensors
14.9.1 Overview and Operation
The Micro-Master Touch includes eight independent switch sensor inputs. Switch sensor inputs are
located on the front panel and can be used as general purpose switch input sensors or inputs for flow
meters.
Each Switch Sensor can be named and can be enabled or disabled.
Switch Sensors enable the controller to monitor specific conditions. e.g. If either the Pressure or
Flow fall outside the required parameters during irrigation, then the station currently irrigating can be
cancelled, and irrigation switched to the next station, before this condition becomes potentially
dangerous or unstable. The most common application of these functions is to monitor the condition
of a normally open, high/low pressure switch (or flow switch) installed in the system mainline. In the
event of a valve not opening (high pressure and no flow) or a pipeline rupture (low pressure and high