Toro Multi Pro 5800-G - Removing the Agitation-Manifold Valve

Toro Multi Pro 5800-G
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
g032545
Figure109
Section-ValveActuatorShown(theagitationvalveactuator
issimilar)
1.Actuator(sectionvalve)3.Stemport
2.Retainer
3.Removetheactuatorfromthemanifoldvalve.
RemovingtheAgitation-Manifold
Valve
1.Removethequickconnectpinthatsecuresthe
quick-connectcouplerfortheagitationhoseto
themanifoldfortheagitationvalve(Figure110).
g191301
Figure110
1.Flange(pressure-lter
head)
4.Quick-connectpin
2.Flange(couplingadapter)5.Quick-connectcoupler
(agitationhose)
3.Flangeclamp
6.Quick-connecttting
(agitation-valvemanifold)
2.Removethe3angeclampsthatsecurethe
agitation-valvemanifoldtotheangesofthe
pressure-lterheadandthecouplingadapter
(Figure110).
3.Removethe2ange-headbolts(1/4x3/4inch)
and2angelocknuts(1/4inch)thatsecurethe
agitation-valvemanifoldtothevalvesupport
(Figure111).
g191302
Figure111
1.Manifold(agitationvalve)4.Flange-headbolt(1/4x
3/4inch)
2.Valvesupport
5.Gasket
3.Flangelocknut(1/4inch)
4.Removetheagitation-valvemanifoldand
gasketsfromthemachine(Figure111).
Note:Ifneeded,loosenthemountinghardware
forthepressure-lterheadasneededtoprovide
clearance.
Note:Retaintheangeclamps,gaskets,and
quick-connectpinsforinstallationinInstalling
theAgitation-ManifoldValve(page85).