Reelmaster 5010 Series Page 5 -- 5 Electrical System
Fault Code (Lamp Flashes)
Fault Description
1--1 High engine temp warning occurred (PTO was shutdown by ECM)
1--2 High engine temp shutdown occurred (engine was shutdown by ECM)
1--3 Low engine oil pressure occurred
1--4 Engine alternator fault occurred
1--5 Charging system voltage was incorrect (check charging system)
1--6 Internal ECM fault
2--1 Check ECM output fuse 1
2--2 Check ECM output fuse 2
2--3 Check ECM output fuse 3
2--4 No power to all ECM output fuses (check main power relay)
2--5 Leak in hydraulic system detected by optional leak detector (reels shutdown
and leak detector alarm sounds)
3--1 Glow plug relay current was too high (check glow plug c ircuit)
3--2 Start relay current was too high (check starting circuit)
3--3 Fuel stop solenoid and fuel pump current were too high
3--5 MSV2 current was too high (check front mow electrical circuit)
4--1 SV1 current was too high (check cutting unit lift electrical circuit)
4--2 SV3 current was too high (check cutting unit lift electrical circuit)
4--3 SV2 current was too high (check cutting unit lift electrical circuit)
4--4 SVRV current was too high (check cutting unit lift electrical circuit)
4--5 MSV1 current was too high (check rear mow electrical circuit)
5--1 Signal from optional leak detector was lost
5--4 Internal ECM fault
Clearing Fault Codes
After fault codes have been retrieved, clearing of those
faults from ECM memory can be completed using the
following switch sequence:
1. Place machine switches in fault retrieval (see
above).Thediagnosticlightshouldbedisplayingthe
fault codes.
2. Operator seat should remain UNOCCUPIED.
3. Move both mow/backlap levers to BACKLAP.
4. Move joystick to the RAISE position.
5. Monitor the diagnostic light for continuous flash-
ing indicating that all faults have been cleared from
ECM memory.
Ifmorethan3faultsexistintheECMmemory,additional
faults can be retrieved using the above procedures. If a
fault is not retrieved from ECM memory within 40 hours
ofmachineoperatingtime,thefaultwillbeautomatically
cleared.