Reelmaster 5010 Series Hydraulic System (Rev. C)Page 4 -- 47
Procedure for Reel Drive Motor Cross--Over
Relief
Pressure
Test
1. Make sure hydraulic oil is at normal operating tem-
perature by operating the machine under load for
approximately ten (10) minutes.
2. Determine which reel motor is malfunctioning.
3. Parkmachineonalevelsurfacewiththecuttingunits
loweredandPTOswitchoff.Makesureengineisoffand
mow/transportleveris in mow. Apply the parking brake.
4. Read Precautions For Hydraulic Testing in this sec-
tion.
CAUTION
Beforeopening hydraulicsystem,operate allhy-
draulic controls to relieve system pressure and
avoid injury from pressurized hydraulic oil. See
RelievingHydraulicSystemPressureintheGen-
eral Information section of this chapter.
NOTE: Thereelmotorsareconnectedinseries.Toiso-
late a faulty motor, all motors in the circuit may have to
betestedbystartingwiththeupstreammotor(closestto
the pump) first.
5. Onreelmotortobetested,thoroughlycleanjunction
of motor inlet and outlet fittings and hydraulic hoses.
Loosen and remove both hoses from fittings. Install a
teefittingwitha 5000 PSI (350 bar) pressure gauge be-
tween fitting and hose for both motor inlet and outlet
(Fig. 44).
6. On the hydraulic mow control manifold, set reel
speedcontroltothefullspeedposition.MakesureMow/
Backlap lever is in the “Mow” position.
7. With cutting units in lowered position and engine
OFF, insert a block of wood between cutting unit reel
blades and carrier frame of c utting unit being tested to
prevent reel from turning (Fig. 43).
8. Startengineandrunatlowidlespeed.Checkforany
hydraulicleakagefromtestconnectionsandcorrectbe-
fore proceeding with test.
CAUTION
Adjacent cutting unit reels will rotate when per-
forming the cross--over relief test. Keep away
from cutting units during test to prevent person-
alinjuryfromrotatingreelblades.Donotstandin
front of the machine.
9. One person should sit on the seat and operate the
machine while another person closely monitors both
pressure gauges connected to the reel motor. Make
sure that engine speed is at low idle position (1200
RPM) andpress PTOswitch to ON.Move“Lower-Mow/
Raise” lever forward to engage the cutting units.
10.There should be a slight hesitation in pressure in-
crease on the inlet side of motor as the cross over relief
valve opens. Once the relief valve is open, there will be
a pressure differential between the gauges on the inlet
and outlet side of the motor. Note and record this pres-
sure difference which should be:
Pressure differential between the two gauges
should be approximately 1800 PSI (124 bar)
11.Disengage the cutting units and stop the engine. If
themeasuredpressure differentialis notapproximately
1800 PSI (124 bar), the cross-over relief valves on the
tested motor may be leaking or damaged. Inspect relief
valves in the reel motor (see Reel Motor Service in the
Service and Repairs section of this c hapter).
12.After testing is completed, make sure that engine is
stopped,thenrelievecuttingunithydraulicsystempres-
sure (see Relieving Hydraulic System Pressure in the
General Information section of this chapter). Remove
pressuregaugesandteefittingsfrommachine.Connect
hydraulic hoses to reel motor fittings.
13.If necessary, test other reel motors.
1. Hydraulic reel motor
2. Reel motor inlet hose
3. Reel motor outlet hose
Figure 44