Page #66 background imageLoading...
Page #66 background image
CheckingtheConditionofCooling
SystemComponents
ServiceInterval:Every300hours
Checktheconditionofthecoolingsystemforleaks,damage,
dirt,andloosehoses,andclamps.Clean,repair,tighten,and
replacethecomponentsasnecessary.
CheckingtheConcentrationofthe
Coolant
ServiceInterval:Every1,000hours
Testtheconcentrationofethyleneglycolbasedantifreezein
thecoolant.Ensurethatthecoolantisamixtureof50%
ethyleneglycoland50%water.
CleaningtheCoolingSystem
ServiceInterval:Every2,000hours/Every2years
(whichevercomesrst)
Thecoolantcapacityoftheengineandtheradiator:18.5
L(19.5USqt).
DrainingtheCoolantfromtheSystem
Important:Donotpourcoolantontothegroundorinto
anunapprovedcontainerthatcanleak.
1.Removetheleftandrightsidepanels;referto
RemovingtheSidePanels(page45).
2.Removethe2hex-headboltsthatsecurethereservoir
doortothehoodandopenthedoor(Figure98).
3.Removetherecovery-tankcapfromthetank(Figure
98).
4.Slipacoolantresistanthosethatis3/8x30inchesover
theoutletforthedrainvalveintheradiator(Figure99).
Figure99
5.Securethehosetothedrainvalvewithahoseclamp
(Figure99).
6.Routethehosedownandthroughtheholeinthelower
mountingplateforthebackllblade(Figure100).
Figure100
7.Placeadrainpanwithaminimumcapacityof23L(6
gallons)undertheopenendofthedrainhose(Figure
100).
8.Openthedrainvalveontheradiator,andallowthe
coolanttodraincompletely.
Note:Disposeoftheusedcoolantproperlyaccording
tolocalcodes.
66

Table of Contents

Other manuals for Toro RT1200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toro RT1200 and is the answer not in the manual?

Toro RT1200 Specifications

General IconGeneral
BrandToro
ModelRT1200
CategoryTractor
LanguageEnglish

Related product manuals