EasyManuals Logo

Toro RT1200 User Manual

Toro RT1200
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
CheckingtheCoolantLevelin
theReservoir
ServiceInterval:Beforeeachuseordaily
Iftheengineoverheatwarningisdisplayedonthecontrol
panel,checkthecoolantlevelinthereservoirandaddcoolant
ifitislow .Alsoinspecttheenginecompartmentaroundthe
radiatorandclearawayanyobstructionstoairow.
1.Parkthemachineonalevelsurface,stoptheengine,
andremovetheignitionkey.
2.Allowtheenginetocool.
3.Removetheleftsidepanel;refertoRemovingtheSide
Panels(page45).
4.Checkthecoolantlevelinthereservoir(Figure25).
2
1
g024979
Figure25
1.Reservoir
2.Coolantlevel(halfway
betweentheAddandFull
marks)
Note:Ensurethatthecoolantlevelisbetween1/4
and3/4ofthewayupinthesightglass(Figure25).
5.Addthespeciedcoolantuntilthecoolantlevelis
between1/4and3/4ofthewayupinthesightglass.
Note:Ensurethatthecoolantsolutionisthoroughly
mixedbeforellingthereservoir.
6.Installtheleftsidepanel;refertoInstallingtheSide
Panels(page46).
CheckingtheHydraulic-Fluid
Level
ServiceInterval:Beforeeachuseordaily
UseToroPremiumAll-seasonHydraulicFluid(available
in5-gallonpailsor55-gallondrums.SeethePartsCatalogor
anAuthorizedToroServiceDealerforpartnumbers).
IfTorohydraulicuidisnotavailable,youmayusean
equivalenthydraulicuid,providedthatitmeetsallthe
followingmaterialpropertiesandindustryspecications.Do
notuseasynthetichydraulicuid.Consultwithyour
lubricantdistributortoidentifyasatisfactoryproduct.
HighViscosityIndex/LowPourPoint
Anti-wearHydraulicFluid,ISOVG46
MaterialProperties:
St@40°C(104°F):44to48 Viscosity,ASTMD445
St@100°C(212°F):7.9to8.5
ViscosityIndexASTM
D2270
140to160
PourPoint,ASTMD97-37°C(-34°F)to-45°C(-49°F)
FZG,Failstage
11orbetter
Watercontent(newuid)500ppm(maximum)
IndustrySpecications:VickersI-286-S(QualityLevel),
VickersM-2950-S(Quality
Level),DenisonHF-0
Note:Manybrandsofhydraulicuidarealmostcolorless,
makingitdifculttodetectleaks.Areddyeadditiveforthe
hydraulicsystemoilisavailablein20ml(0.68oz)bottles.
Onebottleissufcientfor15.1to22.7L(4.0to6.0US
gal)ofhydraulicuid;youcanorderthisadditivefroman
AuthorizedToroServiceDealer.
1.Parkthemachineonalevelsurface,andputallthe
attachmentsinthetransportposition.
2.Stoptheengine,settheparkingbrake,andremovethe
ignitionkey.
3.Checkthehydraulic-uidlevelinthesightglasslocated
atthesideofthehydraulicreservoir(Figure26).
26

Table of Contents

Other manuals for Toro RT1200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toro RT1200 and is the answer not in the manual?

Toro RT1200 Specifications

General IconGeneral
BrandToro
ModelRT1200
CategoryTractor
LanguageEnglish

Related product manuals