Page 5 - 7 Electrical SystemSand Pro 2040Z
General Run Problems
Problem Possible Causes
Engine stops when motion control handles are moved
from the neutral locked position.
Operator seat is not occupied.
Parking brake is applied.
Seat switch or circuit wiring is faulty.
Parking brake or circuit wiring is faulty.
Wiring to interlock components is loose, corroded or
damaged (see electrical schematic and wire harness
drawings in Chapter 7 - Electrical Drawings).
Battery does not charge. Fuse F2 (25 amp) is open, loose or missing.
Wiring to charging circuit components is loose,
corroded or damaged (see electrical schematic and
wire harness drawings in Chapter 7 - Electrical
Drawings).
Charge relay or circuit wiring is faulty.
Ignition switch or circuit wiring is faulty.
Battery is faulty.
Voltage regulator is faulty.
Alternator stator is faulty.
Rear attachment does not raise or lower. Fuse F3 (10 amp) is open, loose or missing.
Wiring to rear attachment circuit components is loose,
corroded or damaged (see electrical schematic and
wire harness drawings in Chapter 7 - Electrical
Drawings).
Rear attachment switch is faulty.
Hydraulic control manifold solenoid coils or circuit
wiring are faulty.
A hydraulic problem in the attachment lift/lower circuit
exists (see Troubleshooting section of Chapter 4 -
Hydraulic System).