E721 RADF jam Original not reaching read sensor: An original which
has passed the original registration sensor (while its
front side is being scanned) or the reverse sensor
(while its back side is being scanned) does not
reach the read sensor.
Ch.5.1.4
E722 Original not reaching large original exit sensor (dur-
ing scanning): An original which has passed the
read sensor does not reach the large original exit
sensor when this original is transported from the
scanning section to the exit section.
Ch.5.1.4
E723 Original not reaching small original reverse sensor
(during scanning): An original which has passed the
read sensor does not reach the small original
reverse sensor when this original is transported
from the scanning section to the reverse section.
Ch.5.1.4
E724 Original stopping at registration sensor: The trailing
edge of the original does not pass the registration
sensor after its leading edge has reached the regis-
tration sensor.
Ch.5.1.4
E725 Original stopping at read sensor: The trailing edge
of the original does not pass the read sensor after
its leading edge has reached the read sensor.
Ch.5.1.4
E726 Transport/exit signal reception jam: The RADF has
received the transport/exit signal from the equip-
ment while no original is at the exposure waiting
position.
Ch.5.1.4
E728 Original not reaching small original exit sensor (dur-
ing scanning): An original which has passed the
read sensor does not reach the small original exit
sensor when this original is transported from the
scanning section to the exit section.
Ch.5.1.4
E731 Original stopping at large original exit sensor: The
trailing edge of the original does not pass the large
original exit sensor after its leading edge has
reached the large original exit sensor.
Ch.5.1.4
E732 Original stopping at small original exit sensor: The
trailing edge of the original does not pass the small
original exit sensor after its leading edge has
reached the small original exit sensor.
Ch.5.1.4
E733 Original not reaching large original exit sensor (exit
section)
Ch.5.1.4
E741 Original stopping at small original reverse sensor:
The trailing edge of the original does not pass the
small original reverse sensor after its leading edge
has reached the small original reverse sensor.
Ch.5.1.4
E742 Original not reaching small original reverse sensor
(during reverse feeding): The leading edge of the
original does not reach the small original reverse
sensor when this original is fed out of the reverse
section.
Ch.5.1.4
E743 Original not reaching small original exit sensor (dur-
ing reverse feeding): An original which has passed
the small original reverse sensor does not reach the
small original exit sensor when this original is exited
out of the reverse section.
Ch.5.1.4
E751 Original stopping at original intermediate transport
sensor: The trailing edge of the original does not
pass the original intermediate transport sensor after
its leading edge has reached the original intermedi-
ate transport sensor.
Ch.5.1.4