© 2005 - 2007 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO520/523/600/603/720/723/850/853
FIRMWARE UPDATING
6 - 17
6
When the FROM basic section software version to be updated is "V1.03 / 8.30" or earlier:
Fig. 6-18
When the FROM basic section software version to be updated is "V1.04 / 2.38" or later:
Fig. 6-19
(9) Turn OFF the power, remove the download jig and install the cover plate.
(10) Perform the initialization of the updating data.
• Turn ON the power while [0] button and [8] button are pressed simultaneously.
• Key in “947”, and then press the [START] button.
• Press the [INITIALIZE] button.
06/09