(1) Select [08 SETTING MODE]. Set “1” for code [9059].
• During automatic calibration, the paper type can be selected and image quality control will be
automatically performed.
Value for 08-9059
After setting the value, use the next procedure.
(2) Perform automatic calibration to correct variations in image density.
* [ADMIN] is selected from among the [CALIBRATION DISPLAY LEVEL] options by default. In other
words, an administrator is authorized to operate the automatic calibration. But the [USER] option can also
be selected to allow the user to operate it. Refer to the MFP Management Guide for further information
regarding how to select the [CALIBRATION DISPLAY LEVEL] option.
* Perform each adjustment for 600dpi and 1200dpi.
* Use steps (a) through (k) to perform the automatic calibration.
(a) Press [USER FUNCTIONS] on the Control Panel to enter the “User Functions” menu.
(b) Press [ADMIN].
(c) Enter an administrator password of 6 to 64 digits. Press [OK].
(d) Press [GENERAL].
(e) Press [CALIBRATION].
(f) Press [600dpi PRINT] or [1200dpi PRINT].
(g) Press the button for the paper type to be corrected.
(h)Press [DEFAULT] to set the default calibration setting, or [CALIBRATION] to adjust the calibration
setting.
* When you press [DEFAULT], the system maintains the default calibration setting for the selected job
type and returns to the previous screen.
* When you press [CALIBRATION], a chart is printed out and the calibration guide illustration is
displayed on the control panel. Proceed to the next step.