3-6
3. Printer-specific Adjustments
(i) Place the paper type (A4/LT size) selected in (g) on the bypass tray.
(j) Place the printed chart face down on the original glass aligning it with its left rear corner, so that two
black rectangular marks are on the left side.
(k) Press the [START] button on the control panel.
* The calibration begins. Do not operate the equipment until the message “Scanning and calibrating”
disappears.
* If the chart is not properly placed, the message “Set chart correctly” is displayed on the control panel. In
this case, return to step (j) and realign the chart.