HX7+ ASD Installation and Operation Manual 103
VI/II Torque Reference Setpoint #2
Program Torque Setting Setpoints VI/II
This parameter is used to set the gain and bias of the VI/II input terminal when
the VI/II terminal is used as the control input while operating in the Torque
Control mode.
This is accomplished by establishing an associated V/f output pattern for a
given VI/II input level.
See VI/II Speed Reference #1 for further information on this setting.
This parameter sets VI/II Torque Reference Setpoint #2 and is the output
torque value that is associated with setting of VI/II Speed Reference #2 while
operating in the Torque control mode.
Direct Access Number — F206
Parameter Type — Numerical
Factory Default 100.00
Changeable During Run — Ye s
Minimum — 0.00
Maximum — 250.0
Units — %
Frequency Mode #2
Program Fundamentals Standard Mode Selection
This parameter selects the source of the frequency command signal to be used
as Frequency Mode #2 in the event that Frequency Mode #1 is disabled or if
Frequency Mode #2 is set up as the primary control parameter. See F004 and
F200 for additional information on this setting.
Settings:
1 — Use VI/II
2 — Use RR
3 — Use RX
4 — Use Option Card RX2
5 — Use CN8 Option (LED Keypad)
6 — Use Binary/BCD Input
7 — Use Common Serial (TTL)
8 — Use RS232/RS485
9 — Use Communication Card
10 — Use Motorized Pot. Simulation
11 — Use Pulse Input Option
Direct Access Number — F207
Parameter Type — Selection List
Factory Default VI/II
Changeable During Run — Ye s
Mode #1/#2 Switching Frequency
Program Fundamentals Standard Mode Selection Mode #1/#2
Switching Frequency
This parameter sets the threshold frequency that will be used in F200 to
determine if Frequency Source #1 or #2 will control the output of the ASD.
See F200 or additional information on this setting.
Direct Access Number — F208
Parameter Type — Numerical
Factory Default 1.0
Changeable During Run — Ye s
Minimum — 0.1
Maximum — Max. Freq. (F011)
Units — Hz
F206 F208