HX7+ ASD Installation and Operation Manual 107
RR Torque Reference Setpoint #2
Program Torque Setting  Setpoints RR
This parameter is used to set the gain and bias of the RR input terminal when 
the RR terminal is used as the control input while operating in the Torque 
Control mode.
This is accomplished by establishing an associated V/f output pattern for a 
given RR input level.
See RR Speed Reference #1 for further information on this setting.
This parameter sets RR Torque Reference Setpoint #2 and is the output torque 
value that is associated with setting of RR Speed Reference #2 while operating 
in the Torque control mode.
Direct Access Number —  F215
Parameter Type — Numerical
Factory Default — 100.00
Changeable During Run — Ye s
Minimum — 0.00
Maximum — 250.0
Units — %
F215 F215