HX7+ ASD Installation and Operation Manual 111
RX2 Speed Reference #1
Program Frequency Setting  Speed Reference Setpoints  RX2
This parameter is used to set the gain and bias of the RX2 input terminal when 
the RX2 terminal is used as the control input while operating in the Speed 
Control mode or the Torque Control mode.
RX2 Input Speed Control Setup
Perform the following setup to allow the system to receive Speed control input 
at the RX2 input terminal:
•Program Fundamentals Standard Mode Selection Frequency 
Mode #1 RX2.
•Program Fundamentals Standard Mode Selection Command 
Mode Use Terminal Board.
•Set RX2 Speed Reference #1 (F222) — the input signal level that 
represents RX2 Speed Frequency #1.
•Set RX2 Speed Frequency #1 (F223).
•Set RX2 Speed Reference #2 (F224) — the input signal level that 
represents RX2 Speed Frequency #2.
•Set RX2 Speed Frequency #2 (F225).
•Provide a Run command (F and/or R).
Once set, as the RX2 input changes, the output frequency of the ASD will vary 
in accordance with the above settings.
This parameter sets RX2 Speed Reference #1 and is the input signal level that 
is associated with the setting of RX2 Speed Frequency #1 while operating in 
the Speed Control mode.
RX2 Input Torque Control Setup
Perform the following setup to allow the system to receive Torque control input 
at the RX2 input terminal:
•Program Fundamentals Standard Mode Selection Frequency 
Mode #1 RX2.
•Program Fundamentals Standard Mode Selection Command 
Mode Use Terminal Board.
•Set RX2 Speed Reference #1 (F222) — the input signal level that 
represents RX2 Torque Reference Setpoint #1.
•Set RX2 Torque Reference Setpoint #1 (F226).
•Set RX2 Speed Reference #2 (F224) — the input signal level that 
represents RX2 Torque Reference Setpoint #2.
•Set RX2 Torque Reference Setpoint #2 (F227).
•Provide a Run command (F and/or R).
Once set, as the RX2 input changes, the output torque of the ASD will vary in 
accordance with the above settings.
This parameter sets RX2 Speed Reference #1 and is the input signal level that 
is associated with the setting of RX2 Torque Reference Setpoint #1 while 
operating in the Torque Control mode.
Direct Access Number —  F222
Parameter Type — Numerical
Factory Default — 00.0
Changeable During Run — Ye s
Minimum — -100.0
Maximum — 100.0
Units — %
Frequency Settings
Note: The speed control response 
may be further trimmed by 
adjusting the Bias and 
Gain settings.
Torque Settings
F222 F222