Station Apparatus
Telephone Installation
8-2 Strata CTX I&M 10/02
Telephone Installation
Digital Telephone System Connection
The following provides information on how to connect all 3000-series DKTs to the Strata CTX
systems. 3000-series DKTs can be connected to the BDKU/BDKS and/or the PDKU interface
PCB. To obtain all capabiltities, the DKT3000-series telephone must be connected to the BDKU/
BDKS. For details on feature availability per station PCB, see Table 8-1.
Before installing any telephone wiring, read the following warning and caution notes:
Table 8-1 DKT3000 Operation with Strata CTX and DK Systems
DKT3000 Telephone
and Feature
Strata CTX System
with BDKU/BDKS
Strata CTX system w/ PDKU
and DK System w/ PDKU or BDKU
DKT3020/3010 Basic LCD 2 x 24 characters 2 x 16 characters, left-justified
DKT3014 Large LCD
8 x 24 characters with VM
and Directory Dial softkeys
2 x 16 characters, left-justified,
no VM and Directory Dial softkeys
LCD )HDWXUH button Operational Not operational
Fixed 6SGLDO button Operational Not operational
DKT3000 telephones per cabinet slot 16 telephones max. 8 telephones max.
DKT3000 Programming Mode “A” (Beep
Tone On/Off, etc.) Program Mode “A” is for
telephone options that are controlled by
the ROM inside the telephone.
Operational Operational
DKT3000 Programming Mode “B” (Flexible
Buttons, One Touch, etc.) Program Mode
“B” is for telephone options controlled by
the Strata CTX670 processor and
database memory. (See the Strata CTX
DKT3000/2000-series Digital Telephone
User Guide.)
Operational
Strata CTX with PDKU is
operational. DK system with PDKU
or BDKU is not operational.
WARNING!
Never install the telephone wiring during a lightning storm.
Never install the telephone jacks in wet locations, unless the jack is specifically
designed for wet locations.
Never touch uninsulated telephone wires or terminals unless the telephone line has
been disconnected at the network interface.
Use caution when installing or modifying telephone lines.
If telephone, DSS console, door phone control box, or door phone wiring exits the
building, external secondary protection is required. See Chapter 7 – MDF PCB Wiring.