CTX100 Maximum Capacity Configuration Examples
Strata CTX I&M 10/02 1-27
Strata CTX
Configuration
with the exception of RDTU and RPTU PCBs that support more than 16 channels, and BDKU/
BDKS PCBs that support Speaker OCA.
3. RDTU and RPTU PCBs can be placed in any odd numbered slot using the following rules:
• If RDTU or RPTU is placed in Slot 103 (preferred) with 8, 16 or 24 channels, another PCB
can still be installed in S104.
• If RDTU or RPTU is placed in Slots 101, 105, or 107 with 8 or 16 channels, another PCB
can still be installed in the next slot; however, if 17~24 channels are required the next even
slot must be vacant.
4. Digital telephone PCBs that support Speaker OCA can be placed in slots using the following
rules:
• If ADKU, BDKU (without BDKS) or PDKU must support Speaker OCA, it can be installed
in any slot; another PCB can be installed in the next even slot.
• If a BDKU/BDKS PCB must support Speaker OCA it can only be installed in Slot 103;
another PCB can be installed in S104.
CTX100 Maximum Capacity Configuration
Examples
The tables in this section summarize the maximum capacities of digital telephones with various
types of line circuits. A PCB placement diagram for each numbered configuration follows tables.
Digital Telephones and Loop Start Lines With or Without Caller ID
Table 1-11 CTX100 Base Cabinet with Analog, Loop Start Lines
4 Universal Slots
40 Stations (Max.)
24 CO lines (Max.)
44 Stations + Analog loop start lines combined (Max.)
Table No. Stations Analog loop start lines
1-12 40 4 (none can have Caller ID)
1-13 32 8 (all can have Caller ID)
1-14 32 16 (none can have Caller ID)
1-15 16 16 (8 can have Caller ID)
1-16 24
1
1. Using ADKU.
8 (none can have Caller ID)
Table 1-12 CTX100 Base: 40 stations, 4 loop start lines, 0 CLID
S101 S102
S103
1
1. S103 is only 8 DKTs and S104 is only 4 lines because of cabinet
power factor
S104
BDKU/
BDKS
BDKU/
BDKS
ADKU RCOU
16 DKTs 16 DKTs 8 DKTs 4 lines