Strata CTX Configuration
CTX100 Maximum Capacity Configuration Examples
Strata CTX I&M 10/02 1-27
Strata CTX
Configuration
with the exception of RDTU and RPTU PCBs that support more than 16 channels, and BDKU/
BDKS PCBs that support Speaker OCA.
3. RDTU and RPTU PCBs can be placed in any odd numbered slot using the following rules:
If RDTU or RPTU is placed in Slot 103 (preferred) with 8, 16 or 24 channels, another PCB
can still be installed in S104.
If RDTU or RPTU is placed in Slots 101, 105, or 107 with 8 or 16 channels, another PCB
can still be installed in the next slot; however, if 17~24 channels are required the next even
slot must be vacant.
4. Digital telephone PCBs that support Speaker OCA can be placed in slots using the following
rules:
If ADKU, BDKU (without BDKS) or PDKU must support Speaker OCA, it can be installed
in any slot; another PCB can be installed in the next even slot.
If a BDKU/BDKS PCB must support Speaker OCA it can only be installed in Slot 103;
another PCB can be installed in S104.
CTX100 Maximum Capacity Configuration
Examples
The tables in this section summarize the maximum capacities of digital telephones with various
types of line circuits. A PCB placement diagram for each numbered configuration follows tables.
Digital Telephones and Loop Start Lines With or Without Caller ID
Table 1-11 CTX100 Base Cabinet with Analog, Loop Start Lines
4 Universal Slots
40 Stations (Max.)
24 CO lines (Max.)
44 Stations + Analog loop start lines combined (Max.)
Table No. Stations Analog loop start lines
1-12 40 4 (none can have Caller ID)
1-13 32 8 (all can have Caller ID)
1-14 32 16 (none can have Caller ID)
1-15 16 16 (8 can have Caller ID)
1-16 24
1
1. Using ADKU.
8 (none can have Caller ID)
Table 1-12 CTX100 Base: 40 stations, 4 loop start lines, 0 CLID
S101 S102
S103
1
1. S103 is only 8 DKTs and S104 is only 4 lines because of cabinet
power factor
S104
BDKU/
BDKS
BDKU/
BDKS
ADKU RCOU
16 DKTs 16 DKTs 8 DKTs 4 lines