Strata CTX Configuration
CTX100 Maximum Capacity Configuration Examples
1-34 Strata CTX I&M 10/02
CTX100: Analog Tie, DID and/or Ground Start Lines
Table 1-42 CTX100 Base: 16 stations, 12 Tie, DID and/or Ground Start Lines
S101 S102 S103 S104
BDKU/
BDKS
RxxU RxxU
1
1. RxxU can be REMU (Tie), RDDU (DID), or RGLU ground start
lines.
RxxU
16 DKTs 4 lines 4 lines 4 lines
Table 1-43 CTX100 Base: 0 stations, 16 Tie, DID and/or Ground Start Lines
S101 S102 S103 S104
RxxU
1
1. RxxU can be REMU (Tie), RDDU (DID), or RGLU ground start
lines.
RxxU RxxU RxxU
4 lines 4 lines 4 lines 4 lines
Table 1-44 CTX100 Base and Expansion Cabinet with Analog Tie, DID and/or Ground Start
Lines
8 Universal Slots
72 Stations (Max.)
32 CO lines (Max.)
80 Stations + Analog Tie, DID and/or ground start Lines combined
(Max.)
Table No. Stations Analog Tie, DID, and/or Ground Start Lines
1-45 72 12 lines (4 Tie/DID max.)
1-46 64 16 lines (8 Tie/DID max.)
1-47 56 16 lines (12 Tie/DID max.)
1-48 48 16 lines any type
1-49 48 20 lines (16 Tie/DID max.)
1-50 32 24 lines any type
1-51 16 28 lines any type
Table 1-45 CTX100 Base & Expansion: 72 stations, 4 Tie or DID and 8 Ground Start Lines
S101 S102 S103 S104 S105 S106 S107 S108
BDKU/
BDKS
BDKU/
BDKS
ADKU RGLU
2
BDKU/
BDKS
BDKU/
BDKS
RxxU
1
1. RxxU can be REMU (Tie), RDDU (DID), or RGLU ground start lines.
RGLU
2
2. RGLU can not be substituted with REMU or RDDU because of cabinet power factor.
16 DKTs 16 DKTs 8 DKTs 4 lines 16 DKTs 16 DKTs 4 lines 4 lines