Strata CTX100 Installation
Installing the CTX100 Cabinet
2-16 Strata CTX I&M 10/02
4. Replace the power supply if the fuse continues to blow and a defective PCB or short cannot be
found. See “Step 7D: Remove and Replace the Power Supply (if required)” on page 2-17.
Step 7C: Check the Power Factor Indicator and Reset Button
The front panel of APSU112 provides a Power Factor LED and Reset button. If the cabinet power
factor is exceeded by overload of PCBs, the PF LED will turn on.
If the PF LED indicator turns on, press the PF reset button with a pointed tool or pencil. If the
PF LED turns off and does not turn on again it may have been turned on by a current surge
while installing a PCB while the power supply was turned-on.
When a PF alarm is indicated, check that the cabinet power factor is not exceeded using
“Worksheet 7 – System Power Factor Check” on page 1-41. If the Power factor has been
exceeded relocate any PCBs that are causing the PF to be exceeded.
Figure 2-14 Power Supply Connectors Top View
AC Fuse
AC Fuse
AC Cord Third Wire Ground Screw
AC-IN Connector
EXP
Expansion
Cabinet
Power Supply
Jumper
Connector
V1-24 Volt Circuit
Breakers:
Motherboard
FG Wire Screw
V2
BASE
Base Cabinet
Power Supply
Jumper
Connector
5997