Installing the CTX100 Cabinet
Strata CTX I&M 10/02 2-23
Do Not Run Cables Out the Top – Cabling from either cabinet should be routed out the
lower sides, not from the top of the cabinet(s) (see Figure 2-21).
Figure 2-21 Avoid Improper Cable Routing
2. Remove the left or right
cover(s) of the cabinet and
knock out the rectangle(s) to
create a hole for the cables, as
needed (see Figure 2-22).
Note Cables can be run out of
either side of Base or
Expansion cabinets.
3. Connect applicable wiring (e.g.,
modular CO line cords, 25-pair
amphenol connector cables) to
the front of the PCBs as
described earlier.
4. Secure all Amphenol cables to
the cabinets with tie wraps (see
Figure 2-23).
6008
Power SupplyPower Supply
5968
Run cables through cover
knock-outs holes
(on all side covers)
To avoid heat problems,
do not store items on
top of the cabinets.
Figure 2-22 Base and Expansion Cabinet Cables and
Connectors
Figure 2-23 Tie-wrap Cables