Register Function / Title Bank Mask Adjustment Range Multiplier
98 BINARY INPUT STD OR
ADJUSTABLE
0 / 1 0001 0000: Standard (0)
0001: Adjustable (1)
99 1 BINARY REF
SETTING POINT #1
0 / 1 00FF 0000 ∼ 0064 (0 ∼ 100) 1
9A BINARY REF POINT
#1 FREQUENCY
0 / 1 FFFF -Fmax ∼ Fmax 0.02
9B BINARY REF
SETTING POINT #2
0 / 1 00FF 0000 ∼ 0064 (0 ∼ 100) 1
9C BINARY REF POINT
#2 FREQUENCY
0 / 1 FFFF -Fmax ∼ Fmax 0.02
9D JOG RUN FREQUENCY 0 / 1 FFFF 0000 ∼ 07D0 (0.00 ∼ 20.00) 0.01
9E Other
than 0
JOG STOP
METHOD
0 / 1 00C0 0000: Decelerated stop (0)
0040: Coast stop (1)
0080: DC injection stop (2)
9F PRESET SPEED
SELECTION
0 / 1 000F 0000 ∼ 000F (0 ∼ 15) 1
A0 ∼ FF Reserved
100 Other
than 0
PRESET SPEED
MODE
ACTIVATION
0 / 1 0004 0000: Deactivated (0)
0004: Activated (1)
101 PRESET SPEED
#1 FREQUENCY
1 FFFF LL ∼ UL 0.01
102 PRESET SPEED
#1 OPERATING
MODE
1 040C 0004: (0)
0000: (1)
000C: (2)
0008: (3)
0404: (4)
0400: (5)
040C: (6)
0408: (7)
1
103 2 or
higher
PRESET SPEED
#2 FREQUENCY
1 FFFF LL ∼ UL 0.01
104 PRESET SPEED
#2 OPERATING
MODE
1 040C Same as PRESET SPEED #1
OPERATING MODE
1
105 3 or
higher
PRESET SPEED
#3 FREQUENCY
1 FFFF LL ∼ UL 0.01
106 PRESET SPEED
#3 OPERATING
MODE
1 040C Same as PRESET SPEED #1
OPERATING MODE
1
107 4 or
higher
PRESET SPEED
#4 FREQUENCY
1 FFFF LL ∼ UL 0.01
108 PRESET SPEED
#4 OPERATING
MODE
1 040C Same as PRESET SPEED #1
OPERATING MODE
1
109 5 or
higher
PRESET SPEED
#5 FREQUENCY
1 FFFF LL ∼ UL 0.01
10A PRESET SPEED
#5 OPERATING
MODE
1 040C Same as PRESET SPEED #1
OPERATING MODE
1
10B 6 or
higher
PRESET SPEED
#6 FREQUENCY
1 FFFF LL ∼ UL 0.01
10C PRESET SPEED
#6 OPERATING
MODE
1 040C Same as PRESET SPEED #1
OPERATING MODE
1
10D 7 or
higher
PRESET SPEED
#7 FREQUENCY
1 FFFF LL ∼ UL 0.01
10E PRESET SPEED
#7 OPERATING
MODE
1 040C Same as PRESET SPEED #1
OPERATING MODE
1