Local/remote key function (=)
With this function, the means of starting and stopping operation and setting frequencies can be switched easily
between the operation panel and the means selected with the parameters (command mode selection) and
(frequency setting mode selection).
To switch between them, set the parameter to and use the EASY key.
Local mode: When Local mode selected by key, start and stop, and frequency setting are
effective only by operation panel keys.
The EASY key lamp is lit while Local mode selected.
Remote mode : Start and stop, and frequency setting follow the selection of (Command
mode),or (Frequency setting mode).
Setting mode – Switching of commands and references
EASY
Commands
Terminal board
O
eration
anel
Logic input: 48
Communication
priority cancel
References
Terminal board
(VI/II,RR,RX)
Local/Remote
RS485
communication
References
O
eration
anel
Communication
option
UP/DOWN
RS485
communication
Key
Logic input: 104
Frequency reference
priority switching
Communication
option
Optional
Terminal board
(VI/II,RR,RX)
O
eration
anel
VI/II
Logic input: 108
Command terminal
board priority
Logic input: 106
VI/II terminal priority
Communication
option
RS485
communication
UP/DOWN
Optional
O
eration
anel
Operation
panel
Terminal
board
Serial communication
Serial communication
Run / Forward
Run / Reverse
Internal
reference
EASY