E6581386
F-44
6
[Parameter setting]
Title Function Adjustment range Default setting
Acceleration time 2 [Note]~ sec. According to model
Deceleration time 2 [Note]~ sec. According to model
Panel acceleration/deceleration selection
: Acceleration/deceleration 1
: Acceleration/deceleration 2
Note: The minimum setting of acceleration and deceleration times have been set respectively at 0.1 sec. by default,
but they can be changed within a range of 0.01 sec. (setting range:0.01~600.0 sec.) by changing the setting
of the parameter (default setting). For details, refer to Section 5.20.
1) Selection using parameters
Time [s]
Output frequency [Hz]
0
Time [s]
=
=
Acceleration/deceleration time 1 is initially set as the default. Acceleration/deceleration time 2 can be selected by
changing the setting of the .
Enabled if = (operation panel input enabled).
2) Switching by frequencies - Automatically switching acc/dec times at certain frequencies
Title Function Adjustment range Default setting
Acceleration/deceleration switching frequency ~ Hz
(3) Deceleration at the gradient corresponding
to deceleration time
(4) Deceleration at the gradient corresponding
to deceleration time
(1) Acceleration at the gradient corresponding
to acceleration time
(2) Acceleration at the gradient corresponding
to acceleration time
(1) (2) (3) (4)
Time [s]0
Output frequenc
Hz
Set frequency