E6581386
F-45
6
3) Switching using external terminals - Switching the acceleration/deceleration time via external terminals
(3) Deceleration at the gradient corresponding
to deceleration time
(4) Deceleration at the gradient corresponding
to deceleration time
(1) Acceleration at the gradient corresponding
to acceleration time
(2) Acceleration at the gradient corresponding
to acceleration time
Output frequency [Hz]
(1)
(2) (3) (4)
cceleration/deceleration
switching signal
Time [s]
0
Setting parameters
a) Operating method: Terminal input
Set the command mode selection to .
b) Use the S2 terminals for switching. (Instead, other terminals may be used.)
Title Function Adjustment range Setting value
Input terminal function selection 6 (S2) ~
(Acceleration/deceleration
switching signal 1)
Acceleration/deceleration pattern
Acceleration/deceleration patterns can be selected individually, using the acceleration/deceleration 1 and 2
parameters.
1) Straight acceleration/deceleration
2) S-pattern acceleration/deceleration 1
3) S-pattern acceleration/deceleration 2
Title Function Adjustment range Default setting
Acceleration/deceleration 1 pattern :Straight, :S-pattern 1, :S-pattern 2
Acceleration/deceleration 2 pattern :Straight, :S-pattern 1, :S-pattern 2
1) Straight acceleration/deceleration
A general acceleration/deceleration pattern.
This pattern can usually be used.
Output frequency [Hz]
Maximum frequency
Time [s]
0