6.24 Operating a synchronous motor
 ,    : PM motor constant 1
,    : Step-out detection current level/ detection time
This parameter is used only when the inverter is used with a synchronous motor. If you intend to use your inverter with
a synchronous motor, contact us at the your supplier.
6.25 Acceleration/deceleration 2
6.25.1 Setting acceleration/deceleration patterns and switching
acceleration/deceleration patterns 1 and 2
  : Acceleration time 2
 : Deceleration time 2
 : Acceleration/deceleration 1 pattern
 : Acceleration/deceleration 2 pattern
 : Panel acceleration/deceleration selection
 : Acceleration/deceleration switching frequency
• Function
Four acceleration times and two deceleration times can be specified individually. The selection/switching
mode can be selected from the following 3 options:
1) Selection by means of parameters
2) Switching by means of frequencies
3) Switching by means of terminals
[Parameter setting]
Title Function Adjustment range Default setting
 Acceleration time 2 [Note]~ sec. According to model
 Deceleration time 2 [Note]~ sec. According to model
 Panel acceleration/deceleration selection
:Acceleration/deceleration 1
: Acceleration/deceleration 2
Note:The minimum setting of acceleration and deceleration times have been set respectively at 0.1 sec. by default,
but they can be changed within a range of 0.01 sec. (setting range:0.01~600.0 sec.) by changing the setting of
the parameter  (default setting).
⇒ For details, refer to Section 5.20.
1) Selection using parameters
Time [s]
Output frequency [Hz]
 
 
 
 
 
0
Time [s]
=
=
Acceleration/deceleration time 1 is initially set as the default. Acceleration/deceleration time 2 can be selected by
changing the setting of the .
Enabled if = (operation panel input enabled).