E6581386
H-7
8
[Setup values of monitor indication parameters (~)]
Communication
No.
Default
setting
Item displayed Marking Unit (Panel)
Unit
(Communication)
FD00 Output frequency Depends on 0.01Hz
FE02 Frequency command value Depends on 0.01Hz
FE03 Output current 1% or 0.01%
FE04 Input voltage (DC detection) 1% or 0.01%
FE05 Output voltage 1% or 0.01%
FE15 Compensated frequency Depends on 0.01Hz
FE16 Speed feedback (real-time value) Depends on 0.01Hz
FE17 Speed feedback (1-second filter) Depends on 0.01Hz
FE18 Torque 1% 0.01%
FE19 Torque command 1% 0.01%
FE20 Torque current 1% 0.01%
FE21 Exciting current 1% 0.01%
FE22 PID feedback value Depends on 0.01Hz
FE23 Motor overload factor (OL2 data) 1% 0.01%
FE24 Inverter overload factor (OL1 data) 1% 0.01%
FE25
Regenerative braking resistance
overload factor (OLr data)
1% 1%
FE28
Regenerative braking resistance load
factor (% ED)
1% 1%
FE29 Input power k 0.1kW 0.01kW
FE30 Output power 0.1kW 0.01kW
FE39 Optional AI2 input 1% 0.01%
FE35 RR/S4 input 1% 0.01%
FE36 VI/II input 1% 0.01%
FE37 RX input 1% 0.01%
FE38 Optional AI1 input 1% 0.01%
FE40 FM output 10.01
FE41 AM output 10.01
(FA65) Communication data output [Note 3] [Note 3] [Note 3]
FE66
Attached to expansion I/O card 1 CPU
version
--
FE67
Attached to expansion I/O card 2 CPU
version
--
FE76 Integral input power k Depends on
Depends on
FE77 Integral output power Depends on
Depends on
FE00 Signed output frequency Depends on 0.01Hz
FE02 Signed frequency command value Depends on 0.01Hz
FE15 Signed compensated frequency Depends on 0.01Hz
FE16
Signed speed feedback (real-time value)
Depends on 0.01Hz
FE17
Signed speed feedback (1-second filter)
Depends on 0.01Hz
FE18 Signed torque 1% 0.01%
FE19 Signed torque command 1% 0.01%
FE20 Signed torque current 1% 0.01%
FE22 Signed PID feedback value Depends on 0.01
FE37 Signed RX input 1% 0.01%
FE38 Signed optional AI2 input 1% 0.01%
FE90 Output speed 1min
-1
1min
-1
FA15
Communication option
Reception counter
11
FA16
Communication option
Error counter
11
Note 1: If any value other than the values in the above table is specified, the number “” is displayed.
Note 2: If a negative value is specified, the negative sign “-” is displayed. The negative sign “-” is affixed only to values
displayed on the monitor. Keep in mind that no sign is affixed to any values read through a communications
device.
Note 3: Data set with FA65-FA79 is displayed.
⇒ For details, refer to Instruction Manual (E6581413) specified in Section 6.36.
[Note 2]
[Note 2]
[Note 2]
[Note 2]
[Note 2]
[Note 2]
[Note 2]
[Note 2]
[Note 2]
[Note 2]
[Note 2]