E6581386
E-8
5
+The functions assigned to the following control input terminals (contact input: ⇒ Refer to Section 7.2) are always
activated regardless of the settings of the command mode selection  and frequency setting mode selection 1
.
• Reset terminal (default setting: RES, valid only for tripping)
• Power removal terminal (assigned to PWR by default)
• Emergency stop terminal
+To make changes in the command mode selection  and the frequency setting mode selection 1  first
stop the inverter temporarily.
No change can be made to them if the inverter is in operation.
Q Preset speed operation
: Set this parameter at  (terminal board).
: Any setting is valid.
1) Setting the run, stop and operation frequencies with the operation panel
Title Function
Example of setting
 Command mode selection
 (Operation
panel input)
Frequency setting mode
selection 1
 (Operation
panel input)
 
Run/stop :Press the     and    keys
on the operation panel
+To switch between forward run and reverse run,
use the forward/reverse run selection .
 
Speed command :Press the       and
keys on the operation
panel to set the frequency.
Motor
IM
CCA
F
R
PWR
R/L1
P24/PLC
Shorted by a shorting bar when
shipped from the factory.
Power
supply
S/L2
T/L3
U/T1
V/T2
W/T3
RX
VI/II
RR/S4
PP
To save the frequency, press
the ENTER key. Then, 
and the set frequency are
displayed alternately for a
while.
Inverter
RUN STOP