192 
Rx_Only) to Tx&Rx (or Tx_Only), the fast start mechanism will be enabled, that 
is, the transmit interval will be shorten to a second, and several LLDPDUs will 
be sent out (the number of LLDPDUs equals this parameter). The default value 
is 3. 
Command Mode 
Global Configuration Mode 
Example 
Specify the Transmit Interval of LLDPDU as 45 seconds and Trap message to 
NMS as 120 seconds: 
TP-LINK(config)# lldp timer tx-interval 45 
TP-LINK(config)# lldp timer notify-interval 120 
lldp med-fast-count 
Description 
The  lldp med-fast-count command is used to configure the number of the 
LLDP-MED frames that will be sent out. When LLDP-MED fast start mechanism 
is activated, multiple LLDP-MED frames will be transmitted based on this 
parameter. The default value is 4. To return to the default configuration, please 
use no lldp med-fast-count command. 
Syntax 
lldp med-fast-count count 
no lldp med-fast-count 
Parameter 
count  ——  Configure the Fast Start Count parameter. It ranges from 1 to 10. By 
default, it is 4. 
Command Mode 
Global Configuration Mode 
Example 
Specify Fast Start Count as 5: 
TP-LINK(config)# lldp med-fast-count 5 
lldp admin-status 
Description