Parameterization and configuration
TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany
Page 106 of 131 TR - ECE - BA - DGB - 0060 - 05 02/23/2017
Operating parameter Lower limit switch / Upper limit switch
Description see page 118
DDLM_Set_Prm
unsigned32
Byte
31
32
33
34
Bit
31 24
23 16
15 8
7 0
Data
2
31
2
24
2
23
2
16
2
15
2
8
2
7
2
0
Default (dec.)
0
Lower limit switch
DDLM_Set_Prm
unsigned32
Byte
35
36
37
38
Bit
31 24
23 16
15 8
7 0
Data
2
31
2
24
2
23
2
16
2
15
2
8
2
7
2
0
Default (dec.)
4096
Upper limit switch
Operating parameter Data bits SSI-Interface
Description see page 118
DDLM_Set_Prm
unsigned8
Byte
39
Bit
7 0
Data
2
7
2
0
Default (dec.)
24
Operating parameter Velocity)
Description see page 118
DDLM_Set_Prm
unsigned8
Byte
40
Bit
7 0
Data
2
7
2
0
Default (dec.)
1

Table of Contents