6.9.9 Code SSI-Interface
Defines the output code for the SSI interface.
6.9.10 Code PROFIBUS-Interface
Defines the output code for the PROFIBUS interface.
6.9.11 Preset 1 / Preset 2
Risk of injury and damage to property by an actual value jump when the
Preset adjustment function is performed!
The preset adjustment function should only be performed when the
measuring system is at rest, otherwise the resulting actual value jump must
be permitted in the program and application!
Defines the position value to which the measuring system is adjusted with the leading
edge of the 1st or 2nd external preset input. To suppress interference, however, the
preset is only carried out if the preset signal is present without interruption during the
entire response time of 30 ms. A re-execution of the preset is not possible until the
input signal has been reset again and a filter time of 30 ms has been waited.
programmed total measuring length in increments – 1,
within 33 554 432
Preset 1 = 0, Preset 2 = 1