3.0 OPERATION
4. Low Battery Voltage
The Lobat/Start Chrg System Status message is displayed when the
battery voltage drops below a safe level. The red Error LED illuminates and the
Buzzer sounds. The inverter shuts off to prevent damage to the batteries.
Provide an ac supply (such as shore power or a generator) to the inverter/
charger to automatically start charging the batteries.
Figure 50
Error Display–Low Battery Voltage
26
System Status:
Lobat/Start Chrg
Inverter
Charge
Batt. Full
Error
822-4A-001
Error LED ON
Error Condition
Remedy
Buzzer Sounds
NOTE: Press any arrow push-button to cancel the buzzer.
3. High Battery Voltage
The Hibat/Stop Chrg System Status message is displayed when the
battery voltage is too high. Switch off any other charging sources to allow the
voltage level to drop. The inverter automatically resets and resumes operation
when the battery reaches a safe voltage level. This condition usually occurs only
when an additional charging source is used to charge the battery bank.
Figure 49
Error Display–High Battery Voltage
System Status:
Hibat/Stop Chrg
Inverter
Charge
Batt. Full
Error
822-4A-001
Error LED ON
Error Condition
Remedy
Buzzer Sounds
NOTE: Press any arrow push-button to cancel the buzzer.

Table of Contents

Other manuals for Trace Engineering RC7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trace Engineering RC7 and is the answer not in the manual?

Trace Engineering RC7 Specifications

General IconGeneral
BrandTrace Engineering
ModelRC7
CategoryRemote Control
LanguageEnglish