Transition Networks SGPAT10xx-x05 PoE+ Converter User Guide
33719 Rev. C https://www.transition.com Page 12 of 49
6-Position DIP Switch Model Summary
The DIP switch default is all in the UP position. The DIP switch default setting is valid until CLI DIP Switch Override
is Enabled (it is disabled by default). The DIP Switch functions are summarized by model number below.
DIP SW 1: Reserved
DIP SW 2: Reserved
DIP SW 3: ALPT: UP=Disabled, DOWN=Enabled
DIP SW 4: Reserved
DIP SW 5: Reserved
DIP SW 6: Reserved
DIP SW 1: Reserved
DIP SW 2: Reserved
DIP SW 3: ALPT: UP=Disabled, DOWN=Enabled
DIP SW 4: Reserved
DIP SW 5: Reserved
DIP SW 6: Reserved
DIP SW 1: Port 2 100/1000 or SGMII mode: UP=100/1000, DOWN=SGMII
DIP SW 2: Reserved
DIP SW 3: ALPT: UP=Disabled, DOWN=Enabled
DIP SW 4: Reserved
DIP SW 5: Reserved
DIP SW 6: Reserved
DIP SW 1: Port 2 100/1000 or SGMII mode: UP=100/1000, DOWN=SGMII
DIP SW 2: Port 3 100/1000 or SGMII mode: UP=100/1000, DOWN=SGMII
DIP SW 3: ALPT: UP=Disabled, DOWN=Enabled*
DIP SW 4: Redundant mode: UP=Normal, DOWN=Redundant
DIP SW 5: Revertive mode: UP=Revertive, DOWN=Non-Revertive (See Note 1)
DIP SW 6: Reserved
DIP SW 1: Port 3 100/1000 or SGMII mode: UP=100/1000, DOWN=SGMII
DIP SW 2: Port 4 100/1000 or SGMII mode: UP=100/1000, DOWN=SGMII
DIP SW 3: ALPT: UP=Disabled, DOWN=Enabled (See Note 3)
DIP SW 4: Redundant mode: UP=Normal, DOWN=Redundant (See Note 2)
DIP SW 5: Revertive mode: UP=Revertive, DOWN=Non-Revertive (See Note 1)
DIP SW 6: 2-Converter mode: UP=Disabled, DOWN=Enabled
Note 1: Available only when Redundant mode is active or enabled.
Note 2: Available only when 2-Converter mode is not active or disabled.