Flow Control (f Command)
This command lets you view and enable or disable SGPAT Flow Control for the port specified in the command.
f – Flow Control {PORT 1-4} {Disable: 0 | Enable: 1}
Type f and press the Enter key on the keyboard to display the current stored flow control setting.
Type f10 and press the Enter key to disable flow control on port 1.
Type f11 and press the Enter key to enable flow control on port 1.
Type f20 and press the Enter key to disable flow control on port 2.
Type f21 and press the Enter key to enable flow control on port 2.
Type f30 and press the Enter key to disable flow control on port 3.
Type f31 and press the Enter key to enable flow control on port 3.
Type f40 and press the Enter key to disable flow control on port 4.
Type f41 and press the Enter key to enable flow control on port 4.
Operation is the same on all models.
f Command Example:
f – Flow Control {PORT 1-4} {Disable:0 | Enable:1}
example: f10 – FC Port 1 Disable, f21 – FC Port2 Enable
%f
Flow Control Status
Port 1:Enabled
Port 2:Enabled
Port 3:Disabled
Port 4:Disabled
%f?
Flow Control Status
Port 1:Disabled
Port 2:Disabled
Port 3:Disabled
Port 4:Disabled
%f11
Flow Control Mode Stored
%