Transition Networks SGPAT10xx-x05 PoE+ Converter User Guide
33719 Rev. C https://www.transition.com Page 32 of 49
Get PSE Status Report (g Command)
This command displays current SGPAT status.
g – Get PSE Status Report
Type g and press the Enter key to show the PD detection, classification, voltage, current and power.
Model Descriptions
SGPAT1013-105, SGPAT1039-105, SGPAT1040-105, SGPAT1040-205: Only Copper Port 1 of these models will
display the status of the PD as seen by the PSE controller.
SGPAT1040-305: Both Copper Port 1and 2 of this model will display the status of the PD as seen by the PSE
controller.
g Command Example:
%g
PSE Port 1:
Class State: Unknown
Detect State: Short
Current Reading: 0.000
Voltage Reading: 0.000
Wattage Reading: 0.000
PSE Port 2:
Class State: Unknown
Detect State: Short
Current Reading: 0.000
Voltage Reading: 0.000
Wattage Reading: 0.000
%