Cabling
Perform all configuration and cabling before powering the SGPAT.
Installing Copper Cable
1. Locate an Ethernet 10/100/1000Base-TX compliant copper cable with male RJ-45 connectors installed at both
ends.
2. Connect the RJ-45 connector at one end of the cable to the SGPAT’s Ethernet 10/100/1000Base-RJ-45 port.
3. Connect the RJ-45 connector at the other end of the cable to the Ethernet 10/100/1000Base-RJ-45 port on
the other device (IP camera, VOIP phone, WAP, etc.).
Note: The AutoCross feature allows the use of either straight-through or crossover configuration cables.
Installing Fiber Cable
1. Locate a 1000Base-X compliant fiber cable with male, two-stranded TX to RX connectors installed at both
ends.
2. Connect the fiber cables to the media converter’s 1000Base-X fiber port as described below:
• Connect the male TX cable connector to the female TX connector.
• Connect the male RX cable connector to the female RX connector.
3. Connect the fiber cables to the 1000Base-X fiber port on the other device (another media converter, hub, etc.)
as described below:
• Connect the male TX cable connector to the female RX connector.
• Connect the male RX cable connector to the female TX connector.