Status LEDs
The SGPAT front panel Status LEDs are shown and described below.
PWR: On = Power being applied to converter
PoE+: Off = No PD detected
On (green) = Power Applied
On (yellow) = Detected Fault
On (yellow Blink) = PoE Classification Fault
TP – Left LED per Port: On (Yellow) = Half Duplex Link
Blink (Yellow) = Half Duplex Activity
On (Green) = Full Duplex Link
Blink (Green) = Full Duplex Activity
TP – Right LED per port: Off = 10Mbps
Yellow = 100Mbps
Green = 1000Mbps
Fiber L/A – per port: 100FX/1000X mode:
On (Yellow) = Link
Blink (Yellow) = Activity
On (Green) = Link
Blink (Green) = Activity
SGMII Mode:
On (Green) = Link
Blink (Green) = Activity
PSE Status LED Error Indicators
1 Blink Yellow = Measured Resistance Signature (Rsig) too Low. End device signature resistance is too low (300
ohm to 15K ohm detected).
2 Blink Yellow = Measured Rsig to High. End device signature resistance is too high (33K ohm to 500K ohm
detected).
4 Blink Yellow = Measured Capacitance (Cpd) too High.
5 Blink Yellow = PD Over Current Condition. Power overload fault.
6 Blink Yellow = PD Other error (Power or Time Out error).