EasyManua.ls Logo

Transition Networks SGPAT1013-105 - Status Leds; PSE Status LED Error Indicators

Transition Networks SGPAT1013-105
49 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Transition Networks SGPAT10xx-x05 PoE+ Converter User Guide
33719 Rev. C https://www.transition.com Page 13 of 49
Status LEDs
The SGPAT front panel Status LEDs are shown and described below.
PWR: On = Power being applied to converter
PoE+: Off = No PD detected
On (green) = Power Applied
On (yellow) = Detected Fault
On (yellow Blink) = PoE Classification Fault
TP – Left LED per Port: On (Yellow) = Half Duplex Link
Blink (Yellow) = Half Duplex Activity
On (Green) = Full Duplex Link
Blink (Green) = Full Duplex Activity
TP – Right LED per port: Off = 10Mbps
Yellow = 100Mbps
Green = 1000Mbps
Fiber L/A – per port: 100FX/1000X mode:
On (Yellow) = Link
Blink (Yellow) = Activity
On (Green) = Link
Blink (Green) = Activity
SGMII Mode:
On (Green) = Link
Blink (Green) = Activity
PSE Status LED Error Indicators
1 Blink Yellow = Measured Resistance Signature (Rsig) too Low. End device signature resistance is too low (300
ohm to 15K ohm detected).
2 Blink Yellow = Measured Rsig to High. End device signature resistance is too high (33K ohm to 500K ohm
detected).
4 Blink Yellow = Measured Capacitance (Cpd) too High.
5 Blink Yellow = PD Over Current Condition. Power overload fault.
6 Blink Yellow = PD Other error (Power or Time Out error).