Transition Networks SGPAT10xx-x05 PoE+ Converter User Guide
33719 Rev. C https://www.transition.com Page 42 of 49
Temperature of Converter (t Command)
This command displays SGPAT and SFP temperature information in Degrees Celsius.
t Internal Temperature of Converter and SFP
Type t and press the Enter key to display the current temperature of the SGPAT and SFP devices (if available).
Operation is the same on all models.
t Command Example:
t Temperature of Switch
%t
Temperature SW = 31 Degrees C
NO DMI Port 3
Temperature Port 4 = 45 Degrees C
%
Reset to Factory Defaults (x Command)
This command returns the SGPAT to the original factory default settings.
x Factory Defaults
Type v and press the Enter key to reset the SGPAT to its factory default settings. Operation is the same on all
models.
x Command Example:
%x
CLI Factory Defaults Stored
%x ?
CLI Factory Defaults Stored
%
Messages
Message: PSE 0 Timer Disable
Meaning: The converter has set a 2-3 minute time out period internally.
Recovery: See the Active Link Pass Through (ALPT) (a Command) on page 27.